Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
BMC Anesthesiol ; 23(1): 386, 2023 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-38007426

RESUMO

BACKGROUND: Incomplete sealing of tracheal diverticula by a tracheal tube cuff during positive-pressure ventilation causes barotrauma but the concrete possibility of incomplete sealing has not been indicated. We aimed to assess the possibility of incomplete sealing in a simulated situation of tracheal intubation for patients with tracheal diverticula with tube fixation where the tracheal tube's vocal cord guide overlaps with the patient's vocal cord. METHODS: We retrospectively assessed the characteristics of tracheal diverticula based on thoracic computed tomography data in our institution from January 2018 to July 2020. Then, we assessed the structural parameters of three single-lumen tracheal tubes (Parker Flex-Tip [Parker Medical, Bridgewater, CT, USA], Portex Soft Seal [ICU Medical, San Clemente, CA, USA], and Shiley TaperGuard [Medtronic, Dublin, Ireland]; 6.0-8.0 mm inner diameter size) and simulated the positional relationships between tracheal diverticula and the tracheal tube during tracheal intubation where the vocal cord guide overlaps with the patient's vocal cord. We assessed each tube product's possibility of incompletely sealing tracheal diverticula and the possibility of unintended bronchial intubation. RESULTS: In 5,854 patients, the prevalence of tracheal diverticula was 5.7%. The mean (SD) length from the vocal cord to the distal end of the tracheal diverticula was 52.2 (12.8) mm. Tracheal tubes with length from the distal end of the tracheal cuff to the vocal cord guide of ≥ 70 mm had a low risk of incompletely sealing tracheal diverticula (< 5%) and length from the distal end of the tube to the vocal cord guide of ≤ 95 mm had a low risk of unintended bronchial intubation (< 5%). No products in this study satisfied both outcomes. CONCLUSIONS: Tube fixation, where the vocal cord guide overlaps with the patient's vocal cord, is associated with risk of incompletely sealing of tracheal diverticula depending on the tube's manufacturer and tube's inner diameter size, although it was not a high risk. The use of small inner diameter sized tube relative to patient's body size is high risk of incomplete sealing of tracheal diverticula. TRIAL REGISTRATION: This trial was prospectively registered at University Hospital Medical Information Network (UMIN). CLINICAL TRIAL NUMBER AND REGISTRY URL: UMIN000043317 (URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000048055 ).


Assuntos
Divertículo , Doenças da Traqueia , Humanos , Anestesia Geral , Intubação Intratraqueal/métodos , Respiração Artificial/métodos , Estudos Retrospectivos , Doenças da Traqueia/terapia
3.
Int J Chron Obstruct Pulmon Dis ; 18: 1931-1935, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37675197

RESUMO

The risk of foreign body aspiration associated with uncapped handheld metered-dose inhalers (MDIs) is underestimated. We report a case in which a plastic cable clip accidentally lodged in the mouthpiece of an uncapped pressurized MDI was aspirated during its use. A literature search revealed 16 other cases of foreign body aspiration associated with uncapped handheld inhalers, all but one of which were pressurized inhalers. Patients should be informed of the risk of foreign body aspiration associated with uncapped pocket inhalers. The use of an uncuffed armoured tracheal tube with a separate oxygen tubing during flexible bronchoscopy for foreign body removal ensures a safe airway. Foreign bodies that exceed the lumen size of the tracheal tube can be pulled to the distal opening with forceps and removed when the tube is withdrawn.


Assuntos
Corpos Estranhos , Doença Pulmonar Obstrutiva Crônica , Humanos , Inaladores Dosimetrados , Nebulizadores e Vaporizadores , Broncoscopia/efeitos adversos , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
4.
Paediatr Anaesth ; 33(11): 905-912, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37386873

RESUMO

BACKGROUND: Conventionally, tracheal tubes have been used for general anesthesia in pediatric laparoscopic surgeries. Recently, supraglottic devices are being used for the same. The performance of supraglottic devices versus tracheal tubes in children undergoing laparoscopic surgery is uncertain. METHODS: A systematic review and meta-analysis of randomized controlled trials that compared supraglottic devices versus tracheal tubes in patients ≤18 years undergoing laparoscopic surgery under general anesthesia was conducted. The outcomes were peak airway pressures (cm H2 O), end-tidal carbon dioxide during pneumoperitoneum (mm Hg), recovery time (min), postoperative sore throat and adverse events. Mean difference and odds ratio, with 95% confidence intervals were reported using a random effect model. RESULTS: Eight trials (n = 591) were included in the final meta-analysis. There was no statistically significant difference in the peak airway pressures (MD 0.58, 95% CI: -0.65 to 1.8; p = .36) and end-tidal carbon dioxide (MD -0.60, 95% CI: -2.00 to 0.80; p = .40) during pneumoperitoneum in the supraglottic device and the tracheal tube group. The tracheal tube group had higher odds of sore throat (OR 3.30, 95% CI: 1.69-6.45; p = .0005) and the supraglottic airway group had faster recovery time (MD 4.21, 95% CI: 3.12-5.31; p < .0001), which were statistically significant. The certainty of evidence is graded low. CONCLUSION: There is low quality evidence to suggest that for pediatric laparoscopic surgeries of short duration, supraglottic devices could provide comparable intraoperative ventilation in terms of peak airway pressures and end tidal carbon dioxide, with lower odds of postoperative sore throat and faster recovery time when compared to tracheal tubes.

6.
Antibiotics (Basel) ; 12(5)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37237704

RESUMO

BACKGROUND: Ventilator-associated lower respiratory tract infectious complications in critically ill patients cover a wide spectrum of one disease process (respiratory infection), initiating from tracheal tube and/or tracheobronchial colonization, to ventilator associated tracheobronchitis (VAT) and ventilator-associated pneumonia (VAP). VAP occurence has been associated with increased intensive care unit (ICU) morbidity (ventilator days, as well as length of ICU and hospital stay) and ICU mortality. Therefore, treatments that aim at VAP/VAT incidence reduction are a high priority. AIM: The aim of the present review is to discuss the current literature concerning two major aspects: (a) can aerosolized antibiotics (AA) administered in a pre-emptive way prevent the occurrence of ventilator-associated infections? and (b) can VAT treatment with aerosolized avert the potential evolution to VAP? RESULTS: There were identified eight studies that provided data on the use of aerosolized antibiotics for the prevention of VAT/VAP. Most of them report favorable data on reducing the colonisation rate and the progression to VAP/VAT. Another four studies dealt with the treatment of VAT/VAP. The results support the decrease in the incidence to VAP transition and/or the improvement in signs and symptoms of VAP. Moreover, there are concise reports on higher cure rates and microbiological eradication in patients treated with aerosolized antibiotics. Yet, differences in the delivery modality adopted and resistance emergence issues preclude the generalisability of the results. CONCLUSION: Aerosolized antibiotic therapy can be used to manage ventilator-associated infections, especially those with difficult to treat resistance. The limited clinical data raise the need for large randomized controlled trials to confirm the benefits of AA and to evaluate the impact on antibiotic selection pressure.

7.
Transl Pediatr ; 12(12): 2222-2231, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38197113

RESUMO

Background: Selecting the optimal tracheal tube size is critically important for pediatric patients. Age-based formulas are often used, but still have limitations. The aim of this prospective study was to investigate whether middle finger measurements correlate with cuffed tracheal tube size and to further develop a prediction model based on these measurements. Methods: Patients under 12 years of age scheduled for elective surgery involving tracheal intubation were enrolled in the study. The length was determined from the tip of the distal metacarpal to the palm's root on the palm side, while the circumference was measured at the base of the palm using a soft tape measure. The appropriate cuffed tracheal tube size was determined based on specific criteria. If the tube encountered resistance during insertion or required an airway pressure >25 cmH2O to detect an audible leak, it was replaced with a tube 0.5 mm smaller. Conversely, if an audible leak occurred at an airway pressure <10 cmH2O, or peak pressure >25 cmH2O, or the cuff pressure >25 cmH2O to achieve a seal, the tube was exchanged for one with a 0.5 mm larger. Linear regression analysis was used to examine the association between middle finger circumference and length with the cuffed tracheal tube size. Subsequently, regression equations were constructed based on the results of the linear regression analysis and their predictive performance was compared to the conventional age-based formulas, including the Khine formula and Motoyama formula. The predictive performance was evaluated by mean absolute error (MAE), root mean square error (RMSE), and prediction accuracy. Results: A total of 261 patients were analyzed in our study. The mean age of the patients was 46.19±35.83 months. The linear relationship was observed between the cuffed tracheal tube size and the middle finger circumference and middle finger length with R2 values of 0.77 and 0.73, respectively. In comparison to conventional age-based formulas, both middle finger circumference and middle finger length demonstrated superior predictive performance, characterized by lower MAE and RMSE, as well as higher prediction accuracy. Notably, the regression equation based on the middle finger circumference obtained the higher predictive accuracy of 0.590, with an MAE of 0.259 and an RMSE of 0.333 as opposed to the predictive accuracy of 0.391, MAE of 0.349, and RMSE of 0.473 derived from conventional age-based formulas. Based on the regression coefficients of linear regression, simplified formulas were proposed, with the middle finger circumference-based formula emerging as the most accurate and simple option. Conclusions: The appropriate cuffed tracheal tube size could be predicted by the middle finger circumference. Our proposed formula 'cuffed tracheal tube internal diameter (mm) = middle finger circumference (cm) - 0.2' has the potential to improve the selection of the cuffed tracheal tube size in pediatric patients.

8.
J Anaesthesiol Clin Pharmacol ; 38(3): 371-383, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36505227

RESUMO

Anatomical differences in the airway in pediatric patients, compared to adults pose many challenges during endotracheal intubation, such as selecting the proper sized endotracheal tube (ETT) during intubation. Our primary objective was to assess how accurate is ultrasound (US) co-relation in comparison to standard age-based formulas in pediatric patients. Meta-analysis was registered in PROSPERO 2020, CRD42020220041. Online literature available in PubMed, Cochrane, and Embase, Goggle scholar was searched from year 2000 till November 30, 2020, using relevant Mesh terms, ('airway US' OR (('airway'/exp OR airway) AND ('US'/exp OR US))) AND ('endotracheal intubation'/exp OR 'endotracheal intubation') AND ('pediatric'/exp OR pediatric)" to Predict endotracheal tube size/placement in pediatric age (neonate till 18 years) by the US. Bibliographic cross-references of selected publications were further manually screened. The full texts of each article were studied, once the abstract was found appropriate independently by two reviewers. A total of 48 papers published between 2010 and 2020 were identified as relevant and read in detail. Average numbers of patients were 86 and total numbers of patients were 1978. Most of the studies included pediatric patients posted for elective surgeries under general anesthesia and excluded emergency procedures, known laryngeal or tracheal pathology, high-risk patients, recent upper respiratory tract infections or allergy to ultrasound gel. A total of 18 independent correlations were analyzed. Final combined r value calculated from all the included articles was 0.824 (95% CI 0.677, 0.908) with a P < 0.00001 {strong co-relation (r > 0.80)}. Q statistic of 756.484, and I2 statistics of 97.53% showed a large degree of heterogeneity in the effect size across the studies. Use of US for upper airway in pediatric patients is an effective modality and can effectively predict endotracheal tube size estimations in comparison to standard age-based or height-based formulae in the pediatric age group. US is a non-invasive, cost-effective, portable, and reproducible technique as compared to CT and MRI. It also takes less time with increasing expertise and experience.

11.
JA Clin Rep ; 8(1): 55, 2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35876976

RESUMO

BACKGROUND: Establishing one-lung ventilation (OLV) in patients with tracheal bronchus (TB) may be challenging due to its unusual bronchial anatomy. We present a case of difficult OLV in a patient with right TB and steeply angled bifurcation of the left main bronchus. CASE PRESENTATION: A 79-year-old woman was scheduled to undergo video-assisted thoracic surgery left upper lobectomy. We planned right OLV with a bronchial blocker; however, it was difficult to place the blocker in the left main bronchus due to a steep bifurcation angle. Therefore, we changed the entry angle of the lumen tip by advancing the tracheal tube to just above the tracheal bifurcation, allowing successful placement of the bronchial blocker into the bronchus. CONCLUSION: For airway management in patients with TB, especially for OLV, it is essential to understand the anatomy of the trachea, bronchus, and TB and to select the appropriate device for each case.

12.
Front Med (Lausanne) ; 9: 920726, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35847807

RESUMO

Background: Surgical retraction to expose the vertebrae during anterior cervical spine surgery increases tracheal tube cuff pressure and may worsen postoperative sore throat and dysphonia. This randomized double-blind study investigated the effect of cuff shape on intraoperative cuff pressure and postoperative sore throat and dysphonia. Methods: Eighty patients were randomized to tracheal intubation with a tapered cuff or a conventional cylindrical high-volume low-pressure cuff (control) during anesthesia. Intraoperative cuff pressures were compared. The primary outcome was the incidence of pressure adjustment needed when the cuff pressure increased to > 25 mm Hg after surgical retraction. The secondary outcome was the incidence of postoperative sore throat and dysphonia. Results: The incidence of pressure adjustment after surgical retraction was significantly lower in the tapered group than in the control group (13% vs. 48%; P = 0.001; relative risk reduction, 74%). The median [interquartile range (IQR)] cuff pressure (mm Hg) was significantly lower for the tapered cuff than for the control cuff before surgical retraction [9 (7-12) vs. 12 (10-15); P < 0.001] and after retraction [18 (15-23) vs. 25 (18-31); P = 0.007]. The median (IQR) postoperative dysphonia score assessed by a single speech-language pathologist was lower in the tapered group than in the control group [4 (3-6) vs. 5.5 (5-7); P = 0.008]. Conclusion: A tapered cuff tracheal tube decreased the need for the adjustment of cuff pressure after surgical retraction during anterior cervical spine surgery, thereby avoiding intraoperative pressure increase. It also has a better outcome in terms of dysphonia. Clinical Trial Registration: [www.clinicaltrials.gov], identifier [NCT04591769].

13.
Ann Med Surg (Lond) ; 76: 103573, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35495371

RESUMO

Background: Post-extubation-atelectasis (PEA) is a common problem after the removal of an endotracheal tube in neonates which increases the rate of extubation failure. Different techniques have been introduced for the prevention of PEA. One technique is the removal of the endotracheal tube by negative or positive gradients of pressure. No RCT has yet been done to compare the use of these two methods in neonates. So this study aimed to compare the role of positive and negative pressure during extubation of neonates on the prevention of PEA. Materials and methods: We enrolled 100 newborns in this RCT that required at least 24 h of mechanical ventilation. The endotracheal tube in one group was removed by a T-Piece resuscitator at a PEEP level of 5 CmH2o while in another group extubation was done applying suction pressure of 100 mmHg by random selection. Prevalence of PEA in CXRs after extubation was compared between the two groups. Results: The prevalence of PEA in the extubation of the positive pressure group (24%) was significantly lower than that of the negative pressure group (46%) (p = 0.024). Extubation failure was found to be lower in the positive pressure group (6% versus 20% P = 0.037). No significant difference was observed between the two groups in the prevalence of apnea, pneumothorax, and death at 3 days after extubation. Conclusion: The use of positive pressure during removal of the endotracheal tube in newborn infants reduced the rate of PEA compared with the negative pressure so extubation by a positive pressure is recommended in neonates.

14.
Anaesthesiol Intensive Ther ; 54(2): 127-131, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35416440

RESUMO

BACKGROUND: Changes in the pressure of cuffed neonatal size tracheal tubes (TT) during anaesthesia without nitrous oxide are not well described. We determined whether the cuff pressure changes over time in neonates under general anaesthesia without nitrous oxide. METHODS: The airways of thirty neonates were secured with a high volume low pressure cuffed TT for meningocele surgery. The cuff was manually inflated until there was no audible leak and maintained at 10-15 cm H2O throughout by monitoring the pressure continuously with both a manometer and a pressure transducer. At baseline, the cuff pressure was assessed in the supine and then prone positions. During surgery, if the pressure exceeded 15 cm H2O, the cuff was deflated to < 15 cm H2O and if it was < 10 cm H2O, the cuff was inflated to 10-15 cm H2O. The time interval between corrections and the number of corrections were recorded. RESULTS: The cuff pressures in 18 neonates (60%) required correction during surgery. The cuff pressure exceeded 15 cm H2O in nine neonates (30%) and was corrected. The cuff pressures in 13 neonates were less than 10 cm H2O and required correction. The gender, weight, height, and duration of anaesthesia did not differ significantly between neonates who required correction of the cuff pressure and those who did not. Mean cuff pressures were similar at 15, 45, and 75 minutes of anaesthesia. CONCLUSIONS: In 60% of neonates undergoing surgery in the prone position under general anaesthesia without nitrous oxide, the cuff pressure exceeded 15 cm H2O. In such cases, cuff pressure should be monitored continuously throughout the surgery.


Assuntos
Intubação Intratraqueal , Óxido Nitroso , Anestesia Geral , Humanos , Recém-Nascido , Pressão , Respiração Artificial
15.
In Vivo ; 36(3): 1195-1202, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35478119

RESUMO

BACKGROUND/AIM: Allicin has been known to improve wound healing via antimicrobial and anti-inflammatory properties. The aim of this study was to evaluate whether an allicin-coated tracheal tube can prevent tracheal stenosis through improving wound healing after tracheal injury. MATERIALS AND METHODS: Allicin-coated silicone tracheal tube (t-tube) was prepared by the polydopamine-mediated coating method. Tracheal mucosa was injured, and an allicin-coated t-tube was placed into the trachea to evaluate mucosal changes until designated time point. Anti-inflammatory, anti-bacterial and cytotoxic effects of allicin were also investigated in in vitro. RESULTS: Allicin- coated silicone was not cytotoxic, and it showed anti-inflammatory and anti-bacterial effects in in vitro analysis. The use of allicin-coated t-tube in a rabbit model showed favorable mucosal healing with significant decrease of proinflammatory cytokines compared to the non-coated tube group. The allicin-coated tube showed obvious decreased number of cocci-shaped bacterial attached to the tube surface. From the histological point of view, the allicin- coated tube showed faster regeneration of the normal respiratory epithelial structure compared to the non-coated group. CONCLUSION: Allicin-coated t-tube showed anti-inflammatory and anti-bacterial effects on injured tracheal mucosa. We suggest that allicin-coated t-tube can be used for promoting physiological wound healing to prevent laryngotracheal stenosis.


Assuntos
Traqueia , Estenose Traqueal , Animais , Anti-Inflamatórios/farmacologia , Bactérias , Dissulfetos , Mucosa , Coelhos , Ácidos Sulfínicos/farmacologia , Estenose Traqueal/prevenção & controle
16.
Br J Anaesth ; 128(2): 382-390, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34920855

RESUMO

BACKGROUND: There is a paucity of evidence regarding the optimal type of tracheal tube to be advanced over a Frova catheter when performing a 'bougie' emergency front-of-neck airway (eFONA) technique in infants during a 'cannot intubate, cannot oxygenate' situation. METHODS: A prospective non-inferiority trial in a rabbit cadaver surgical tracheotomy model to assess the performance of the eFONA technique with an uncuffed 3.5 mm ID tracheal tube vs a cuffed 3.0 mm ID tracheal tube. Queried outcomes include success rate, performance time, and severe secondary airway injuries among tracheal tube types. RESULTS: In 60 tracheostomies performed by 30 participants, the overall success rate was 98%. Performance time was independent from tracheal tube choice (uncuffed: 61 s [95% confidence interval (CI), 52-76], cuffed: 64 s [95% CI, 55-79]; P = 0.82). No tracheal tube type was preferred in terms of usability by participants. The cuffed tracheal tube required increased force to be advanced over the Frova catheter and was associated with a risk ratio of 2.5 (95% CI, 0.53-11.9; number needed to harm, 10) for severe secondary airway injuries when compared with the uncuffed tracheal tube. CONCLUSION: In performing eFONA in the rabbit cadaver model, an ID 3.5 uncuffed is non-inferior to an ID 3.0 cuffed tracheal tube regarding performance time and preference by the operator. Greater force application to advance the cuffed tube over the Frova catheter and more severe airway injuries may argue for the standardised performance of the eFONA technique with a uncuffed tracheal tube in infants.


Assuntos
Intubação Intratraqueal/métodos , Sistema Respiratório/lesões , Traqueotomia/métodos , Animais , Estudos Cross-Over , Desenho de Equipamento , Humanos , Lactente , Intubação Intratraqueal/instrumentação , Modelos Animais , Estudos Prospectivos , Coelhos , Traqueotomia/educação , Traqueotomia/instrumentação
17.
Eur J Trauma Emerg Surg ; 48(3): 1723-1735, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34333690

RESUMO

PURPOSE: Tracheal tube introducers and stylets remain some of the most widely used devices for aiding practitioners in performing endotracheal intubation (ETI). The purpose of this systematic review is to evaluate the efficacy of tracheal tube introducers and stylets for ETI in the prehospital setting. METHODS: A literature search was conducted on the 2nd of March 2021 across PubMed, Embase (Ovid) and the Cochrane Central Register of Controlled Trials (CENTRAL) to identify relevant studies. Included studies had their data extracted and both a quality assessment and statistical analysis were performed. RESULTS: The summary estimate of prehospital studies with video technology showed a statistically significant increase in first pass ETI success in favour of bougies (RR 1.15, CI 1.10-1.21, p < 0.0001). The summary estimates of prehospital studies without video technology and simulation studies with and without video technology showed no statistical difference between methods for first pass or overall ETI success. Some of the highest success rates were recorded by devices that incorporated video technology. Stylets lead to a shorter time to ETI while bougies were easier to use. Neither device was associated with a higher rate of ETI complications than the other. CONCLUSION: Both tracheal tube introducers and stylets function as efficacious aids to intubation in the prehospital environment. Where video technology is available, bougies could offer a statistically significant advantage in terms of first pass ETI success. Where video technology is unavailable, a combination of clinical scenario, practitioner expertise and personal preference might ultimately guide the choice of device.


Assuntos
Serviços Médicos de Emergência , Intubação Intratraqueal , Serviços Médicos de Emergência/métodos , Humanos
18.
Eur Arch Otorhinolaryngol ; 279(3): 1593-1599, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34499203

RESUMO

PURPOSE: Choosing the right tracheal tube for the right patient is a daily preoccupation for intensivists and emergency physicians. Tracheal tubes can generate severe complications, which are chiefly due to the pressures applied by the tube to the trachea. We designed a bench study to assess the frequency of pressure levels likely to cause tracheal injury. METHODS: We tested the pressure applied on the trachea by 17 tube models of a given size range. To this end, we added a pressure sensor to the posterior tracheal wall of a standardized manikin. RESULTS: Only 2 of the 17 tubes generated pressures under the threshold likely to induce tracheal injury (30 mmHg/3.99 kPa). The force exerted on the posterior wall of the trachea varied widely across tube models. CONCLUSION: Most models of tracheal tubes resulted in forces applied to the trachea that are usually considered capable of causing tracheal tissue injury. LEVEL OF EVIDENCE: Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence: How common is the problem?: step 1; Is this diagnostic or monitoring test accurate? (Diagnosis) step 5; What will happen if we do not add a therapy? (Prognosis) n/a; Does this intervention help? (Treatment Benefits) step 5; What are the COMMON harms?(Treatment Harms) step 5; What are the RARE harms? (Treatment Harms) step 5; Is this (early detection) test worthwhile? (Screening) step 5.


Assuntos
Manequins , Traqueostomia , Humanos , Intubação Intratraqueal , Respiração Artificial , Traqueia , Traqueostomia/efeitos adversos
19.
World J Clin Cases ; 9(29): 8915-8922, 2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34734075

RESUMO

BACKGROUND: Trauma is one of the leading causes of death in the pediatric population. Bronchial rupture is rare, but there are potentially severe complications. Establishing and maintaining a patent airway is the key issue in patients with bronchial rupture. Here we describe an innovative method for maintaining a patent airway. CASE SUMMARY: A 3-year-old boy fell from the seventh floor. Oxygenation worsened rapidly with pulse oxygen saturation decreasing below 60%, as his heart rate dropped. Persistent pneumothorax was observed with insertion of the chest tube. Fiberoptic bronchoscopy was performed, which confirmed the diagnosis of bronchial rupture. A modified tracheal tube was inserted under the guidance of a fiberoptic bronchoscope. Pulse oxygen saturation improved from 60% to 90%. Twelve days after admission, right upper lobectomy was performed using bronchial stump suture by video-assisted thoracic surgery without complications. A follow-up chest radiograph showed good recovery. The child was discharged from hospital three months after admission. CONCLUSION: A modified tracheal tube could be selected to ensure a patent airway and adequate ventilation in patients with bronchial rupture.

20.
Can J Anaesth ; 68(9): 1337-1348, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34018159

RESUMO

BACKGROUND: Flexible bronchoscope-guided tracheal intubation through supraglottic airway devices (SGAs) is a well-established element of difficult intubation algorithms. Success can be limited by dimensional incompatibilities between tracheal tubes (TTs) and SGAs. METHODS: In this in vitro study, we tested the feasibility of TT passage through SGAs, removal of SGAs over TTs, and the ability to guide the flexible bronchoscope with 13 TT brands (internal diameter, 6.5-8.0 mm) and ten different SGAs (#4 and #5) in an intubation mannequin. RESULTS: We tested 1,040 combinations of SGAs and TTs. Tracheal tube passage failed in 155 (30%) combinations of the five tested first-generation SGAs (117 [46%] with SGA #4, 38 [15%] with SGA #5) and in three (0.6%) combinations of the five tested second-generation SGAs (two [0.8%] with SGA #4 and one [0.4%] with SGA #5). The reason for failed passage of a TT through a first-generation SGA consistently was a too-narrow SGA connector. Removal of the SGA over the TT in the 882 remaining combinations was impossible for all sizes of reinforced TTs, except the Parker Reinforced TT, and was possible for all non-reinforced TTs. Only one combination with SGA #4 and 84 combinations with SGA #5 were not ideal to adequately guide the flexible bronchoscope. CONCLUSION: Clinically relevant combinations of adult-size TTs and SGAs can be incompatible, rendering flexible bronchoscope-guided tracheal intubation through an SGA impossible. Additional limitations exist regarding removal of the SGA and maneuverability of the flexible bronchoscope.


RéSUMé: CONTEXTE: L'intubation endotrachéale guidée par bronchoscope flexible via un dispositif supraglottique (DSG) est un élément établi des algorithmes utilisés pour les intubations difficiles. La réussite de l'intubation peut être limitée par des incompatibilités dimensionnelles entre les tubes endotrachéaux (TET) et les DSG. MéTHODE: Dans cette étude in vitro, nous avons testé la faisabilité de faire passer un TET par un DSG, le retrait du DSG par-dessus le TET et la possibilité de guider un bronchoscope flexible avec 13 marques de TET (diamètre interne, 6,5-8,0 mm) et dix DSG différents (#4 et #5) sur un mannequin d'intubation. RéSULTATS: Nous avons testé 1040 combinaisons de DSG et de TET. Le passage du tube endotrachéal a échoué dans 155 (30 %) combinaisons avec les cinq DSG de première génération testés (117 [46 %] avec DSG #4, 38 [15 %] avec DSG #5) et dans trois (0,6 %) combinaisons avec les cinq DSG de deuxième génération testés (deux [0,8 %] avec DSG #4 et une [0,4 %] avec DSG #5). La raison de l'échec du passage d'un TET à travers un DSG de première génération était systématiquement liée à un connecteur de DSG trop étroit. Dans les 882 combinaisons restantes, le retrait du DSG par-dessus le TET s'est avéré impossible avec toutes les tailles de TET armés, à l'exception du TET armé Parker, et était possible avec tous les TET non armés. Une seule combinaison avec le DSG #4 et 84 combinaisons avec le DSG #5 n'étaient pas idéales pour guider le bronchoscope flexible de manière adéquate. CONCLUSION: Les combinaisons cliniquement pertinentes de TET et de DSG de tailles adultes peuvent être incompatibles, rendant impossible l'intubation endotrachéale guidée par bronchoscope flexible via un DSG. D'autres limites existent en ce qui concerne le retrait du DSG et la maniabilité du bronchoscope flexible.


Assuntos
Máscaras Laríngeas , Manequins , Adulto , Broncoscopia , Humanos , Intubação Intratraqueal , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...